The system comprises:
a. A software driven locating receiver that guides the user through steps necessary to locate exact route or blockage in duct
b. Traceable duct rodder designed for use in telecom ducts of 26mm inner dia or higher, up to lengths of 300 meters (1000 feet).
c. Miniaturized sonde frequency transmitter, operating at low frequencies, for use in small dia telecom ducts (or larger pipes) which allow the sonde to pass through ducts including bends.
d. Transmitter to energize the CTRAK traceable rodder.
Benefits include:
- Quick detection of route of lost telecom ducts.
2. Confirmation of depths at which ducts had been laid, allowing as-built maps to be updated.
3. Detection of blockages in ducts with precision allowing the field teams to dig at a specific point, especially important in major city or town environments where random digging is not possible.
System Usage description is as follows:
The SONDE operating at 512Hz is attached to the CTRAK Traceable Duct rodder unit & is pushed inside the non-metallic HDPE Conduit or any other line until it stops due to blockage in HDPE pipe or because of entry into the next manhole. The CTRAK contains a 1 sq. mm tracer which is energized by the Line exciter at 8/16/32 or 64 kHz. The digital receiver is then set to receive frequencies at 8/16/32 or 64 kHz to trace direction and route of line in the Line Tracing Mode. Once the trace is completed until the line trace starts to fade, the receiver setting is changed to the Sonde Tracing Mode to receive 512Hz frequency transmitted by the SONDE or any other customized frequency which can then be used to pin point exact point of blockage in HDPE conduit or manhole location.
Please refer features for seeing visual illustrations of steps to be followed to achieve above objectives.
DIGITAL RECEIVER | |
Frequency | Sondes at 16 Hz & 512 Hz & 8kHz & 2 “sniffable” frequencies, |
Line trace | 8, 16, 32 & 64 kHz |
Output LCD screen | Index, Peak locate, Line, Sonde, Track, Power, Sniff,Depth |
Automatic depth detection | 25 feet /7.6 meters ; accurate upto 5% of depth |
Controls | 4-way thumb switch: Power on/off, Gain, Screen select |
Speaker output | Variable rate click; headphone jack. Sound can be muted. |
Power source | 6 AA Alkaline |
Battery life | 30-40 hours (depends on backlight usage) |
Operating temperature | -20 to +130º F / -29 to +54º C |
Weight | 2.7 kg |
Size | 81 cm x 20 cm x 11 cm |
Locate Accuracy | 5% of Depth, depending on depth |
Depth Accuracy | 5% of Depth with undistorted signal, with no |
Adjacent Signals | Upto 14ft/4.3m |
Depth Range | Line -up to 3 m at 5% depth accuracy |
Up to 25 ft / 7.6 m at 10% depth accuracy | |
Sonde – up to 15 ft (with FV-10) | |
Sonde – up to 60 ft / 18.3 m (with FV-40) |
SONDE TRANSMITTER | |
Frequency | 512 Hz |
Tone type | Continuous |
Power source | AAA 1.5V Battery |
Battery life | 8 hours((for continuous uninterrupted use) |
Size | 19 mm x 89mm |
Range (cast iron) | Up to 10 ft |
Range (non-metallic) | Up to 15 ft |
End Adaptor | Female M12 |
BUZZ BOX | |
Operating Modes | Conductive & Inductive |
Frequencies | 8KHz, 16KHz, 32KHz and 64KHz |
Power | 3watts maximum, Lo and Hi power for |
each frequency, uses 6 “C” alkaline | |
batteries, battery life approx. 10 hours continuous | |
Control | Rotary switch ; Off plus 8 frequency/power selections |
Indicators | Low battery LED, Ground quality current meter |
Operating Temperature | 0 – 50 deg C |
Dimensions | 240mmx190mmx110mm |
PIPE TRAKING TRACEABLE MAXI DUCT RODDER (CTRAK) | |
Length Options | 150m(492’), 200m(650’), or 300m(984’) |
Dimension | 33”x20”x37” Maxi Frame “B” Type for 120~200m |
43”x20”x44” Super Maxi Frame “A” Type for 300 m frame | |
Rod Dia | 9.0mm (Nominal) |
Size of Copper Wire | 1mm Dia |
Reviews